Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Asan, Adem" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Simultaneous determination of Nickel(II), Copper(II), and Cobalt(II) in environmental samples at trace levels by reversed-phase high-performance liquid chromatography using shiff base complexes
    (Pleiades Publishing, 2025) Konanç, Mustafa Umut; Asan, Adem
    Abstract: A new method for the simultaneous determination of Ni(II), Cu(II), and Co(II) ions in environmental samples by reversed-phase liquid chromatography was developed. The developed method is based on the synthesis of the quadrivalent Schiff base 6,6'-((1E,1'E)-(ethane-1,2-diylbis(azaneylylidene))bis(methaneylylidene))bis(3-methoxyphenol) by the condensation reaction between 2-hydroxy-4-methoxybenzaldehyde and ethylenediamine. The resulting Schiff base was used as a chelating agent to convert the targeted ions into metal-ligand complexes within 1 min, which were extracted on an octadecylsilane (ODS) solid-phase extraction mini-column and then injected into a reversed-phase high-performance liquid chromatography system. Sufficient separation of the metal-ligand complexes was achieved on a GL Sciences Intersil ODS-3 column with a mobile phase composition of methanol-acetonitrile-water (30 : 30 : 40, v/v) within 6 min and detection by an ultraviolet detector at 254 nm. The limits of detection were found to be 0.45, 0.40, and 1.47 µg/L for Co2+, Cu2+, and Ni2+, respectively. Recoveries from water samples ranged from 97.4 to 103.6%, with relative standard deviation values between 0.4 and 1.7%. While the targeted metal ions were not detected in a sample from the remote upstream area of the Kabaca Stream (Artvin, Turkey), concentrations were found to be 116.4 µg/L for Cu2+ and 32.9 µg/L for Ni2+ in a sample taken from the Kabaca Stream near the industrial area (Artvin, Turkey). Co2+ was below the limit of detection in both cases. In addition, the developed method was also validated using the inductively coupled plasma optical emission spectrometry technique.

| Artvin Çoruh Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Artvin Çoruh Üniversitesi, Artvin, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2026 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim