Experimental investigation of the effects of arterial geometries in different severities of symmetrical stenosis on pressure drop and pump power

dc.authorid0000-0002-9630-1232en_US
dc.contributor.authorSönmez, Fatin
dc.contributor.authorYıldırım, Orhan
dc.contributor.authorKaragöz, Şendoğan
dc.contributor.authorGündoğdu, Fuat
dc.date.accessioned2021-12-23T13:07:58Z
dc.date.available2021-12-23T13:07:58Z
dc.date.issued2021
dc.departmentAÇÜ, Artvin Meslek Yüksekokulu, Makine Bölümüen_US
dc.descriptionThis study was sponsored by Atattirk University Scientific Research Projects Coordination Unit with the grant FCD-2019-7316.en_US
dc.description.abstractnvironmental factors and unhealthy eating damage the cardiovascular structure. This damage, blood and vessel interactions and consequent hemodynamic effects cause cardiovascular diseases. In the study, an experimental system was established by creating models for stenosis caused by environmental factors. The purpose of the experimental study presented is to investigate the effect, pressure drop, peristaltic pump inlet and outlet pressure and most importantly, the amount of power consumed by the peristaltic pump regarding arterial stenosis severity with varying areal stenosis percentages. The tests were performed for the pulse values from 54 to 168 bpm by setting up models with 0%, 60%, 70% and 80% symmetrical stenosis severities. In the study, the pressure difference in the test area increased concomitantly with elevated pulse value and increased stenosis severity. This situation revealed that as the intensity of narrowing increases in vessels, the narrowing space differential pressure increases, and this amount increases even more with increased exertion. The pressure at the peristaltic pump outlet increased concomitantly with elevated pulse value and increased stenosis severity. The peristaltic pump overworked to overcome the increased differential pressure related to the increased pulse value and stenosis severity.
dc.identifier.citationSönmez, F., Yıldırım, O., Karagöz, S., & Gündoğdu, F. (2021). Experimental Investigation of the Effects of Arterial Geometries in Different Severities of Symmetrical Stenosis on Pressure Drop and Pump Power. Fresenius Environmental Bulletin,30-(11A), 12666-12675.en_US
dc.identifier.endpage12675en_US
dc.identifier.startpage12666en_US
dc.identifier.urihttps://hdl.handle.net/11494/3621
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.institutionauthorSönmez, Fatin
dc.language.isoenen_US
dc.publisherParlar Scientific Publicationsen_US
dc.relation.ispartofFresenius Environmental Bulletin
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectEnvironmental factorsen_US
dc.subjectHearten_US
dc.subjectPoweren_US
dc.subjectStenosisen_US
dc.subjectPulseen_US
dc.subjectPressure Dropen_US
dc.titleExperimental investigation of the effects of arterial geometries in different severities of symmetrical stenosis on pressure drop and pump poweren_US
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
Sönmez, Fatin.pdf
Boyut:
3.48 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: