Intraocular pressure measured by rebound tonometry in seven raptor species

dc.authorid0000-0001-8879-4121en_US
dc.contributor.authorYonez, Muhammed Kaan
dc.contributor.authorErol, Maral
dc.contributor.authorErol, Hanifi
dc.contributor.authorAtalan Güneri
dc.contributor.authorDoğan, Zümrüt
dc.contributor.authorKibar, Murat
dc.date.accessioned2022-08-23T09:03:58Z
dc.date.available2022-08-23T09:03:58Z
dc.date.issued2022
dc.departmentAÇÜ, Artvin Meslek Yüksekokulu, Avcılık ve Yaban Hayatı Bölümüen_US
dc.description.abstractThe purpose of this study was to investigate the applicability of Rebound tonometer for the intraocular pressure measurement and to determine the correlation between intraocular pressure reference values and body weight in different raptor species.In the present study, intraocular pressure of 66 Long-legged buzzard (132 eyes), 20 Eurasian sparrowhawk (40 eyes), 13 Eurasian eagle-owl (26 eyes), 6 Golden eagles (12 eyes), 6 Common kestrels (12 eyes), 4 Peregrine falcon (8 eyes), 2 Griffon vulture (4 eyes), which referred to Erciyes University, Faculty of Veterinary Med-icine, Department of Surgery Clinic were evaluated. In the ophthalmologic examination there was no lesion detected related to eyes. The mean body weight raptors was 1.10??0.23 kg in Long-legged buzzard, 0.23??0.06 kg in Eurasian sparrow hawk, 0.27??0.10 in Eurasian eagle-owl, 3.30??0.80 kg in Golden eagles, 0,18??0.04 kg in Common kestrels, 0,64??0,28 kg in Peregrine falcon and 2.28??0.43 kg in Griffon vulture. Rebound tonometer was used for measurement of intraocular pressure. Mean intraocular pressure of right and left eyes were in Long-legged buzzard 25.87??0.62-26.61??0.71, Eurasian sparrow hawk 11.90??0.40-12.05??0.41, Eurasian eagle-owl 12.00??0.63-12.61??0.57, Golden ea-gles 29.00??2.89-30.33??2.87, Common kestrels 11.75??0.17-10.83??0.47, Peregrine falcon 14.75??1.10-14.25??0.85 and Griffon vulture 15.00??1.00-14.50??0.50. As a result of the study, Rebound tonometer is a reliable method for measuring intraocular pressure in small eyes and minimizes stress, well tolerated by raptors in intraocular pressure measurements. While there was a positive correlation detected between body weight and IOP values among the species, no correlation was observed between body weight and IOP values within the same species. The intraocular pressure values obtained in this study will help veterinary ophthalmologists and wild animal veterinarians to evaluate changes intraocular pres-sure in raptor and contribute to the literature.
dc.identifier.citationYönez, M. K., Erol, M., Erol, H., Atalan, G., Doğan, Z., & Kibar, M. (2022). Intraocular Pressure Measured by Rebound Tonometry in Seven Raptor Species. Journal of the Hellenic Veterinary Medical Society, 73(2), 3929-3934.en_US
dc.identifier.doi10.12681/jhvms.21914
dc.identifier.endpage3934en_US
dc.identifier.issue2en_US
dc.identifier.scopusqualityQ4
dc.identifier.startpage3929en_US
dc.identifier.urihttps://hdl.handle.net/11494/4146
dc.identifier.volume73en_US
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorKibar, Murat
dc.language.isoenen_US
dc.publisherHellenic Veterinary Medical Socen_US
dc.relation.ispartofJournal Of The Hellenic Veterinary Medical Society
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectIntraocular pressureen_US
dc.subjectRaptoren_US
dc.subjectRebound tonometeren_US
dc.titleIntraocular pressure measured by rebound tonometry in seven raptor speciesen_US
dc.typeArticle

Dosyalar

Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: