3D printed microwave clamp probe design to detect water level in PVC pipes

dc.authorid0000-0003-1859-5236en_US
dc.contributor.authorKasar, Ömer
dc.contributor.authorGözel, Mahmut Ahmet
dc.contributor.authorGeçin, MustafaA.
dc.date.accessioned2021-11-30T05:35:02Z
dc.date.available2021-11-30T05:35:02Z
dc.date.issued2021
dc.departmentAÇÜ, Mühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümüen_US
dc.descriptionThis work was supported by Artvin Coruh University Scientific Research Projects Coordinator (BAP). Funding Number is 2019.F14.02.01en_US
dc.description.abstractThe permittivity of water is considerably larger than that of air. As the amount of water in PVC water pipes increases, the air will be replaced by water. This means that the electromagnetic environment properties inside the pipe will change. In this study, we proposed a microwave clamp probe designed with a 3D printer that can detect the percentage of water in 50 mm diameter PVC water pipes. The clamp probe allows measurement of return loss from a single port for determining the fill rate of water without any physical intervention from outside the pipe. The clamp, which is structurally similar to a loop antenna, operates at a frequency of 2.45 GHz. As a result of simulations and experimental measurements for different fill percentages of the pipe, the input impedance of the clamp was calculated. Then, an impedance-fill rate graph was created, showing the amount of water in the pipe section according to the impedance values obtained. The impedance seen from the clamp input indicated a linear increase between 40-100 Omega, according to the 0%, 20%, 50%, 80% and 100% of the water in the pipe. The clamp has a compact structure that can be used as a plug-and-play anywhere on the horizontal.
dc.identifier.citationKasar, Ö., Gozel, M. A., & Gecin, M. (2021). 3D Printed Microwave Clamp Probe Design to Detect Water Level in PVC Pipes. Informacije MIDEM, 51(3), 151-155en_US
dc.identifier.doi10.33180/InfMIDEM2021.301
dc.identifier.endpage155en_US
dc.identifier.issue3en_US
dc.identifier.scopusqualityN/A
dc.identifier.startpage151en_US
dc.identifier.urihttps://hdl.handle.net/11494/3567
dc.identifier.volume51en_US
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorKasar, Ömer
dc.language.isoenen_US
dc.publisherSoc Microelectronicsen_US
dc.relation.ispartofInformacije MIDEM -Journal of Microelectronics, Electronic Components and Materials
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMicrowave Clamp Probeen_US
dc.subjectImpedance Analysisen_US
dc.subjectPVC Water Pipeen_US
dc.subjectPipe Fill Rateen_US
dc.subjectLoop Antenna Designen_US
dc.title3D printed microwave clamp probe design to detect water level in PVC pipesen_US
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
omer_kasar.pdf
Boyut:
2.17 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: