Performance improvement of the heat recovery unit with sequential type heat pipes using TİO2 nanofluid

dc.authorid0000-0002-5560-0578en_US
dc.contributor.authorÖztürk, Ahmet
dc.contributor.authorÖzalp, Mehmet
dc.contributor.authorSözen, Adnan
dc.contributor.authorGuru, Metin
dc.date.accessioned2021-02-22T12:46:33Z
dc.date.available2021-02-22T12:46:33Z
dc.date.issued2019
dc.departmentAÇÜ, Artvin Meslek Yüksekokuluen_US
dc.descriptionThis work was supported by Scientific Research Projects Coordination Unit of Karabuk University. Project Number: KBU-BAP-14/2-DR-018.en_US
dc.description.abstractThis paper deals with the improvement of thermal performance of the heat recovery system in air-to-air unit by using a nanofluid of TiO particles and distilled water. The 2 experimental set-up equipped with 15 copper pipes of a 1000 mm length, 10.5 mm inner diameter, and 12 mm outer diameter was used. The evaporator section consists of 450 mm of heat pipes, the condenser section is 400 mm, and the adiabatic section is 150 mm. In experimental studies, 33% of the evaporator volumes of heat pipes were filled with working fluids. Experiments were carried out at temperatures between 25 ºC and 90 ºC by using five different cooling air-flows (40, 42, 45, 61, and 84 g/s), and two different heating powers (3 kW and 6 kW) for the evaporation section, to determine heat removed from the condensation section. Trials were performed for distilled water and nanofluid respectively, and the results were compared with each other. Results revealed that a 50% recovery in the thermal performance of the heat pipe heat recovery system was achieved in the design using TiO nanofluid as the working liquid, at a heating power of 3 kW, air 2 velocity of 2.03 m/s and air-flow of 84 g/s
dc.identifier.citationÖztürk, A., Özalp, M., Sözen, A., & Guru, M. (2019). Performance improvement of the heat recovery unit with sequential type heat pipes using TiO2 nanofluid. Thermal Science, 23(3), 1755-1764.en_US
dc.identifier.doi10.2298/TSCI170703303O
dc.identifier.endpage1764en_US
dc.identifier.issue3en_US
dc.identifier.scopusqualityQ3
dc.identifier.startpage1755en_US
dc.identifier.urihttps://hdl.handle.net/11494/2639
dc.identifier.volume23en_US
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorÖztürk, Ahmet
dc.language.isoenen_US
dc.publisherVinca Inst Nuclear Scien_US
dc.relation.ispartofThermal Science
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectHeat pipeen_US
dc.subjectNanofluiden_US
dc.subjectTiOen_US
dc.subjectHeat recovery uniten_US
dc.titlePerformance improvement of the heat recovery unit with sequential type heat pipes using TİO2 nanofluiden_US
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
ahmet_ozturk.pdf
Boyut:
8.85 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: